Best coriolis mass flowmeter manufacturer: Example mass flow applications – As gas mixtures are often defined in terms of volumetric ratios, mass flow instrumentation is useful for gas mixing applications. As noted above, mass flow is defined by the flow industry as a form of molar flow measurement, which can be confusing since in reality they are molar ratios. In order to make up “volumetric” mixture ratios, one should use mass flow rates. Custody transfer applications benefit from mass flow measurement, simply because it is necessary to know the mass of gas being used. Find extra info on coriolis density meter.
The selection of gas turbine flowmeters is a difficult task for many people. In fact, as long as the relevant precautions are mastered, the selection of gas turbine flowmeters will become very simple. Fully understand the qualifications and performance of gas turbine flow meter suppliers. When purchasing gas turbine flowmeters, imported brands are basically familiar to everyone. However, when purchasing domestic brands, it is necessary to fully understand the qualifications and performance of suppliers. You can get a first-hand account of it by visiting it in person or by asking people who have used the brand before. It is recommended to use brands with high reputation in China, good user reputation and outstanding performance as much as possible.
Influence of humidity on measurement results when using vortex meter. The output of the vortex flowmeter is only proportional to the flow velocity of the fluid flowing through the measuring tube. When measuring wet saturated steam, the influence of water droplets on the output of the turbine flow meter is negligible, so it can be considered that the output of the turbine flow meter is entirely caused by the wet flow. Caused by the dry part of the steam. The density of the dry part, whether it is pressure compensation or temperature compensation, can be detected more accurately. The results of steam measurement are often used as the basis for economic settlement between the supply and demand sides. If the two parties agree to settle the fee according to the dry part of the steam and no charge for the condensed water, the impact of the phase change on the measurement is negligible and can be ignored.
Sincerity first factory of 121 warehouse with one calibration line was officially established Since 2007. The 2nd generation coriolis mass flow meters were officially launched. The coriolis mass flow meters are upgraded with batch control functions. The size of the coriolis mass flow meters are largely reduced, and the display has been upgraded to LCD display (liquid crystal display) . Sincerity 4th generation coriolis mass flow meters were officially launched. They have been upgraded to integrated type coriolis flow meters, with sensor and transmitter. The coriolis flow meters added 0-10KHz, and 4-20mA output. We still need the magnetic bar to calibrate the zero point, and to modify the inner parameters.
Ultrasonic flow meters enable users to perform flow measurement inspections at many points in the flow process without the need for permanent installation. This universal driving time timer has a dual-function button interface, an ergonomic handheld design, and a beautiful backlit color digital display that greatly simplifies setup and data collection. Compared with other traditional flowmeters or high temperature ultrasonic flow meter, it has the characteristics of high accuracy, high reliability, high performance, and low cost. The flowmeter also has other advantages: TVT technology design. Fewer hardware components, low-voltage broadband pulse transmission, and low power consumption. Clear, user-friendly menu selections make the flowmeter easy to use. Daily, monthly and yearly total traffic. The parallel operation of positive, negative, and net flow is displayed cumulatively by a scale factor (span) and a 7-digit number. Discover extra info on https://www.bjssae.com/.
Beijing Sincerity Automatic Equipment Co., Ltd was reformed from the Petrochemical Branch Automatic Equipment Co.,Ltd. Beijing Sincerity is the innovation developed enterprise invested by both the China Petroleum &Chemical Corporation’s Beijing Research Institute of Chemical Industries and the Capital Science and Technology Group. Please be noticed, that all the videos taken are approved by SGS, Switzerland, or TUV, Germany. All the videos are real and without shooting skills or beauty filters.
Install the total steam flow meter before the pressure reducing valve. Since the above-mentioned steam has not been decompressed, there is no phase change problem, so install the flowmeter before the pressure reducing valve, and use the saturated steam compensation method to ensure the measurement Accuracy. If the flowmeter can only be installed behind the pressure reducing valve, a pressure transmitter can be added for temperature and pressure compensation. If the stability of the pressure reducing valve is good, the upstream pressure value of the flowmeter can be set as a constant value in the display instrument for temperature and pressure compensation.